Specifications 
Output Voltage11.88 to 12.12 volts
Input Voltage66 to 154 volts
Output Power200 watts (0.2680 HP)
Operating Temperature-20 to 100 C (-4 to 212 F)

 

Features, Applications

Features
DC input range: 154 V (continuous) Encapsulated circuitry for shock and

to +100C) Input surge withstand: 250 V for ms DC output: 48 V Programmable output: to 110% Regulation: 0.2% no load to full load Efficiency: to 90% Maximum operating temp: 100C, full load Power density: 80 W per cubic inch Height above board: 0.43 in. (10,9 mm) Parallelable, with N+M fault tolerance Low noise ZCS/ZVS architecture RoHS Compliant (with or G pin option) Agency approvals

These DC-DC converter modules use advanced power processing, control and packaging technologies to provide the performance, flexibility, reliability and cost effectiveness of a mature power component. High frequency ZCS/ZVS switching provides high power density with low noise and high efficiency.

Parameter +In to In voltage PC to In voltage PR to In voltage SC to Out voltage Sense to Out voltage Isolation voltage in to out in to base out to base Operating Temperature Storage Temperature Pin soldering temperature Mounting torque Rating 65 to Unit Vdc Vrms C F (C) F (C) in-lbs (N-m) Test voltage Test voltage Test voltage M-Grade < 5 sec; wave solder < 7 sec; hand solder 6 each Notes

Applications

Railway/Transportation system applications including communications systems, information display, lighting, control systems, ticket machines, passenger entertainment, public address systems, door control, industrial power systems and power generation systems.

Pin Style Blank: Short Tin/Lead L: Long Tin/Lead S: Short ModuMate N: Long ModuMate F: Short RoHS G: Long RoHS

For a description of pin options, see page 11. Baseplate options include slotted flanges, threaded and through-hole. See page 12 for dimensions. For other package sizes and power levels, see the Micro (quarter size) and Maxi (full size) datasheets.

Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate.

Parameter Operating input voltage Input surge withstand Undervoltage turn-on Undervoltage turn-off Overvoltage turn-off/on Disabled input current Min 66 Typ 110 Max 250 65.4 Unit Vdc mA PC pin low Notes <100 ms

Parameter Output voltage setpoint Line regulation Temperature regulation Power sharing accuracy Programming range Min Typ Max Unit % Vout nom. C % Notes Nominal input; full load; 25C Low line to high line; full load Over operating temperature range 100% of full load Of nominal output voltage. For trimming below 90% of nominal, a minimum load 10% of maximum rated power may be required. Externally applied Externally applied Externally applied Externally applied Externally applied Externally applied Externally applied Externally applied Externally applied

+Out to Out, +Sense to Out Absolute Maximum Ratings to 62.9

Note: For important information relative to applications where the converter modules are subject to continuous dynamic loading, contact Vicor applications engineering at 800-927-9474.

Parameter Baseplate to sink; flat, greased surface Baseplate to sink; thermal pad (P/N 20265) Baseplate to ambient Baseplate to ambient; 1000 LFM Thermal capacity Min Typ Max Unit C/Watt Watt-sec/C

PRIMARY SIDE (PC = Primary Control; PR = Parallel) PC bias voltage current limit PC module disable PC module enable delay PC module alarm PC resistance PR emitter amplitude PR emitter current PR receiver impedance PR receiver threshold PR drive capability SECONDARY SIDE (SC = Secondary Control) SC bandgap voltage SC resistance SC capacitance SC module alarm Vdc F Vdc With open trim; referenced to Sense. See Fig. 6 Referenced to Sense Vdc mA Vdc ms Vavg M Volts mA Volts modules 25C Minimum pulse width: 20 ns Without PR buffer amplifier UV, OT, module fault. See Figs. 2 and 4 See Fig. 2 PR load pF PC current mA PC voltage 5.5 V Must be able to sink 4 mA. See Fig. 1

Parameter Remote sense (total drop) Isolation test voltage in to out in to base out to base Isolation resistance (in to out) Weight Temperature limiting Agency approvals cURus, TV, 4.0 (113.4) Min Typ Max 0.5 Unit Vdc Vrms M ounces (grams) C See Figs. 2 and CSA60950-1, IEC60950-1. With appropriate fuse in series with the +Input Notes 0.25 V per leg (senses must be closed) Complies with reinforced insulation requirements Complies with basic insulation requirements Complies with operational insulation requirements

Note: Specifications are subject to change without notice.

 

Related products with the same datasheet
V110B12C100B2
V110B12C100B3
V110B12C100BF
V110B12C100BF2
V110B12C100BF3
V110B12C100BG
V110B12C100BG2
V110B12C100BG3
V110B12C100BL
V110B12C100BL2
V110B12C100BL3
V110B12C100BN
Some Part number from the same manufacture Vicor Corporation
V110B12C200BF2 Specifications: Output Voltage: 11.88 to 12.12 volts ; Input Voltage: 66 to 154 volts ; Output Power: 200 watts (0.2680 HP) ; Operating Temperature: -20 to 100 C (-4 to 212 F)
V110B12E100B2
V110B12H100B
 
0-C     D-L     M-R     S-Z